> Thru-beam Type Digital Displacement Sensor HG-T
> Order guide
|
|
|
Type | Measurement width |
Installation distance |
Repeatability (Note 1) |
Laser class | Model No. | |
---|---|---|---|---|---|---|
Measurement width 10 mm 0.394 in |
Standard type |
10 mm 0.394 in |
0 to 500 mm 0 to 19.685 in |
1 μm 0.039 mil [Installation distance: 20 mm 0.787 in] 2.5 μm 0.098 mil [Installation distance: 100 mm 3.937 in] 5 μm 0.197 mil [Installation distance: 500 mm 19.685 in] |
Class 1 [JIS / IEC / GB / FDA (Note 2)] |
HG-T1010 |
Slim type |
HG-T1110 |
Notes:
1) | This is the P-P value of digital measurement value with half shading at the middle position of the installation distance. |
---|---|
2) | This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). |
Type | Appearance | Model No. | Cable length | Description |
---|---|---|---|---|
Sensor head connection cables |
![]() |
CN-HT-C2 | 2 m 6.562 ft |
This cable is used to connect the sensor head to the controller. The cable is branched into two cables on the sensor head connecting side, but the two cables can be connected interchangeably to the emitter and receiver. |
CN-HT-C5 | 5 m 16.404 ft |
|||
CN-HT-C10 | 10 m 32.808 ft |
|||
CN-HT-C20 | 20 m 65.617 ft |
Type | Appearance | Model No. | Output | Maximum number of connectable controllers |
|
---|---|---|---|---|---|
Master unit |
High performance type | ![]() |
HG-TC101 | NPN open-collector transistor |
Up to 15 slave units can be connected per master unit (Note) |
HG-TC101-P | PNP open-collector transistor |
||||
Slave units |
High performance type | ![]() |
HG-TC111 | NPN open-collector transistor |
|
HG-TC111-P | PNP open-collector transistor |
||||
Wire-saving type | ![]() |
HG-TC113 | - |
Note: | When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit. |
---|
Type | Appearance | Model No. | Description |
---|---|---|---|
USB communication unit (Note 1) |
![]() |
SC-HG1-USB | When used together with the "HG-T Configuration Tool" USB-based PC setting software, current values and settings in the HG-T series can be confirmed or changed on the PC screen. * The USB-based PC setting software, "HG-T Configuration Tool," can be downloaded free from our website. • Communication specification: USB 2.0 Full Speed (Note 2) • Communication protocol: Proprietary protocol • USB port: USB Mini-B (1 port) • Number of connectable units Controller: Up to 15 units (1 master unit, 14 slave units) per SC-HG1-USB unit |
Notes:
1) | The USB communication unit cannot be used with contact-type digital displacement sensors HG-S series. |
---|---|
2) | Dependent on PC environment. |
Please check each product page for communication units for Digital Displacement Sensors.
>>CC-Link IE Field / CC-Link Communication Unit
>>Communication Unit for Digital Displacement Sensors SC-HG1(for EtherCAT / RS-485)
Type | Appearance | Model No. | Description |
---|---|---|---|
End plates | ![]() |
MS-DIN-E [2 pcs. per set] |
Always use this when connecting controllers and a digital displacement sensor communication unit. |
|
|