LF Relays

Load for air conditioner 1 Form A 20A power relays

TMP type
PCB type
RoHS規格 UL C-UL Recognaized VDE HOUSE MARK TUV SUD Product service

UL/C-UL , VDE , TUV , TV Approved
CSA standard certified by C-UL

Protective construction: Flux-resistant type

Please refer to "the latest product specifications" when designing your product.
Please refer to "Cautions For Use" in the catalog, and "Related Information" on our website.

Features

1.Ideal for compressor and inverter loads

1.Compressor load: 20A 250V AC
2.Inverter load: 20A 100V AC, 10A 200V AC

2.Long insulation distance

• Creepage distance and clearances between contact and coil;
 Creepage Min. 9.5mm .374inch/ Clearance Min. 8mm .315inch
• Surge withstand voltage: 10,000V

3."PCB" and "TMP" types available

Typical Applications

1.Air conditioner

2.Refrigerators

3.OA equipment