AUTOMATION
CONTROLS

Search
Discontinued
Products



DS Relays

Coil data

  • Operating characteristics such as ‘Operate voltage’ and ‘Release voltage’ are influenced by mounting conditions, ambient temperature, etc.
    Therefore, please use the relay within ± 5% of rated coil voltage.
  • ‘Initial’ means the condition of products at the time of delivery.

1.Single side stable type

Type Rated coil voltage Operate voltage*
(at 20°C)
Release voltage*
(at 20°C)
Rated operating current
(±10%, at 20°C)
Coil resistance
(±10%, at 20°C)
Rated operating power Max. allowable voltage
(at 50°C)
Standard
type
(M)
1.5 V DC Max. 70% V of rated coil voltage (Initial) Min. 10% V of rated coil voltage (Initial) 266.7 mA 5.63 Ω 400 mW 120% V of rated coil voltage
3 V DC 133.3 mA 22.5 Ω
5 V DC 80 mA 62.5 Ω
6 V DC 66.7 mA 90 Ω
9 V DC 44.4 mA 203 Ω
12 V DC 33.3 mA 360 Ω
24 V DC 16.7 mA 1,440 Ω
48 V DC 8.3 mA 5,760 Ω
High
sensitivity
type
(S)
1.5 V DC Max. 80% V of rated coil voltage (Initial) Min. 10% V of rated coil voltage (Initial) 133.3 mA 11.3 Ω 200 mW 160% V of rated coil voltage
3 V DC 66.7 mA 45 Ω
5 V DC 40 mA 125 Ω
6 V DC 33.3 mA 180 Ω
9 V DC 22.2 mA 405 Ω
12 V DC 16.7 mA 720 Ω
24 V DC 8.3 mA 2,880 Ω
48 V DC 4.2 mA 11,520 Ω
*square, pulse drive (JIS C 5442)

2.2 coil latching type

Type Rated coil voltage Set voltage*
(at 20°C)
Reset voltage*
(at 20°C)
Rated operating current
(±10%, at 20°C)
Coil resistance
(±10%, at 20°C)
Rated operating power Max. allowable voltage (at 50°C)
Set coil Reset coil Set coil Reset coil Set coil Reset coil
Standard type (M) 1.5 V DC Max. 70% V of rated coil voltage (Initial) Max. 70% V of rated coil voltage (Initial) 240 mA 240 mA 6.25 Ω 6.25 Ω 360 mW 360 mW 120% V of rated coil voltage
3 V DC 120 mA 120 mA 25 Ω 25 Ω
5 V DC 72 mA 72 mA 69.4 Ω 69.4 Ω
6 V DC 60 mA 60 mA 100 Ω 100 Ω
9 V DC 40 mA 40 mA 225 Ω 225 Ω
12 V DC 30 mA 30 mA 400 Ω 400 Ω
24 V DC 15 mA 15 mA 1,600 Ω 1,600 Ω
48 V DC 7.5 mA 7.5 mA 6,400 Ω 6,400 Ω
High sensitivity type (S) 1.5 V DC Max. 80% V of rated coil voltage (Initial) Max. 80% V of rated coil voltage (Initial) 120 mA 120 mA 12.5 Ω 12.5 Ω 180 mW 180 mW 160% V of rated coil voltage
3 V DC 60 mA 60 mA 50 Ω 50 Ω
5 V DC 36 mA 36 mA 139 Ω 139 Ω
6 V DC 30 mA 30 mA 200 Ω 200 Ω
9 V DC 20 mA 20 mA 450 Ω 450 Ω
12 V DC 15 mA 15 mA 800 Ω 800 Ω
24 V DC 7.5 mA 7.5 mA 3,200 Ω 3,200 Ω
48 V DC 3.75 mA 3.75 mA 12,800 Ω 12,800 Ω
*square, pulse drive (JIS C 5442)

Return to top

Specifications

Item Specifications
Contact data Contact arrangement 1 Form C
Contact resistance (initial) Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Contact material Ag+Au clad
Contact rating (resistive) 2 A 30 V DC
Max. switching power (resistive) 60 W, 125 VA
Max. switching voltage 220 V DC, 250 V AC
Max. switching current 3 A
Min. switching load
(reference value)*1
10 μA 10 mV DC
Insulation resistance (initial) Min. 100 MΩ
(at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric strength (initial) Between open contacts Standard type (M):
1,000 Vrms for 1 min (detection current: 10 mA)
High sensitivity type (S):
500 Vrms for 1 min (detection current: 10 mA)
Between contact and coil Standard type (M):
1,500 Vrms for 1 min (detection current: 10 mA)
High sensitivity type (S):
1,000 Vrms for 1 min (detection current: 10 mA)
Time characteristics (initial) Operate [Set] time Max. 10 ms at rated coil voltage (at 20°C, without bounce)
[Max. 10 ms (at 20°C, without bounce)]
Release [Reset] time Max. 5 ms at rated coil voltage (at 20°C, without bounce, without diode)
[Max. 10 ms (at 20°C, without bounce)]
Shock resistance Functional 490 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Destructive 980 m/s2 (half-sine shock pulse: 6 ms)
Vibration resistance Functional 10 to 55 Hz (at double amplitude of: 3.3 mm, detection time: 10 μs)
Destructive 10 to 55 Hz (at double amplitude of: 5 mm)
Expected life Mechanical life Single side stable: Min. 100 x 106 ope.
Latching: Min. 10 x 106 ope. (at 600 times/min)
Conditions Conditions for usage, transport and storage*2 Ambient temperature: –40 to +70°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Unit weight Approx. 3 g
*1This value is a rough indication of the lower limit at which switching is possible at micro load level.
This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
TX/TX-S/TX-D relay AgPd contact type are available for low level load analog circuit (10 V DC, 10 mA max. level).
*2For ambient temperature, please refer to the “GUIDELINES FOR RELAY USAGE”

Return to top

Electrical life

Conditions: Resistive load, at 60 times/min

Type Switching capacity Number of operations
1 Form C 2 A 30 V DC Min. 500 x 103

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region