TX Relays TH Types

Coil data

  • Operating characteristics such as "Operate voltage" and "Release voltage" are influenced by mounting conditions, ambient temperature, etc.
    Therefore, please use the relay within ±5% of rated coil voltage.
  • "Initial" means the condition of products at the time of delivery.

Single side stable

Rated coil voltage Operate voltage*
(at 20°C)
Release voltage*
(at 20°C)
Rated operating
current
(±10%, at 20°C)
Coil resistance
(±10%, at 20°C)
Rated operating power Max. allowable
voltage
(at 20°C)
1.5 V DC Max. 75% V of rated coil voltage
(Initial)
Min. 10% V of rated coil voltage
(Initial)
93.8 mA 16 Ω 140 mW 150% V of rated coil voltage
3 V DC 46.7 mA 64.3 Ω
4.5 V DC 31 mA 145 Ω
5 V DC 28.1 mA 178 Ω
6 V DC 23.3 mA 257 Ω
9 V DC 15.5 mA 579 Ω
12 V DC 11.7 mA 1,028 Ω
24 V DC 5.8 mA 4,114 Ω
48 V DC 5.6 mA 8,533 Ω 270 mW 120% V of rated coil voltage
*square, pulse drive (JIS C 5442)

2 coil latching

Rated coil voltage Set voltage*
(at 20°C)
Reset voltage*
(at 20°C)
Rated operating current
(±10%, at 20°C)
Coil resistance
(±10%, at 20°C)
Rated operating power Max. allowable voltage
(at 20°C)
Set
coil
Reset
coil
Set
coil
Reset
coil
Set
coil
Reset
coil
1.5 V DC Max. 75% V of rated coil voltage
(Initial)
Max. 75% V of rated coil voltage
(Initial)
93.8 mA 93.8 mA 16 Ω 16 Ω 140 mW 140 mW 150% V of rated coil voltage
2.4 V DC 58.3 mA 58.3 mA 41.1 Ω 41.1 Ω
3 V DC 46.7 mA 46.7 mA 64.3 Ω 64.3 Ω
4.5 V DC 31 mA 31 mA 145 Ω 145 Ω
5 V DC 28.1 mA 28.1 mA 178 Ω 178 Ω
6 V DC 23.3 mA 23.3 mA 257 Ω 257 Ω
9 V DC 15.5 mA 15.5 mA 579 Ω 579 Ω
12 V DC 11.7 mA 11.7 mA 1,028 Ω 1,028 Ω
24 V DC 5.8 mA 5.8 mA 4,114 Ω 4,114 Ω
*square, pulse drive (JIS C 5442)

Return to top

Specifications

Item Specifications
Contact data Contact arrangement 2 Form C
Contact resistance
(initial)
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Contact material Ag+Au plating
Contact rating
(resistive)
2 A 30 V DC, 0.5 A 125 V AC
Max. switching power
(resistive)
60 W (DC), 62.5 VA (AC)
Max. switching voltage 220 V DC, 250 V AC
Max. switching current*1 Inrush current: 7.5 A, Steady state current: 2 A
Min. switching load
(reference value)*2
10 μA 10 mV DC
Insulation resistance
(initial)
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric strength
(initial)
Between open
contacts
1,000 Vrms for 1 min (detection current: 10 mA)
Between contact and coil 2,000 Vrms for 1 min (detection current: 10 mA)
Between contact sets 1,000 Vrms for 1 min (detection current: 10 mA)
Surge withstand voltage
(initial)
Between open contacts 1,500 V 10 x 160 μs
Between contact and coil 2,500 V 2 x 10 μs
Time characteristics
(initial)
Operate (Set) time Max. 4 ms at rated coil voltage (at 20°C, without bounce)
[Max. 4 ms (at 20°C, without bounce)]
Release (Reset) time Max. 4 ms at rated coil voltage (at 20°C, without bounce, without diode)
[Max. 4 ms (at 20°C, without bounce)]
Shock resistance Functional 750 m/s2
(half-sine shock pulse: 6 ms, detection time: 10 μs)
Destructive 1,000 m/s2 (half-sine shock pulse: 6 ms)
Vibration resistance Functional 10 to 55 Hz (at double amplitude of: 3.3 mm, detection time: 10 μs)
Destructive 10 to 55 Hz (at double amplitude of: 5 mm)
Expected life Mechanical life Min. 100 x 106 ope. (Switching frequency: at 180 times/min)
Conditions Conditions for usage,
transport and storage*2
Ambient temperature:
-40 to +85°C (1.5 to 24 V DC), -40 to +70°C (48 V DC)
(Allowable temperature is from -40 to +70°C at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Unit weight Approx. 2 g
*1When using at 7.5 A, please refer to "GUIDELINES FOR USAGE, Max. switching current".
*2This value is a rough indication of the lower limit at which switching is possible at micro load level.
This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*3For ambient temperature, please refer to the “GUIDELINES FOR RELAY USAGE”.

Return to top

Electrical life

Conditions: resistive load, switching frequency at 20 times / minute

Type load Switching capacity Number of operations
2 Form C Resistive load 1 A 30 V DC Min. 500 x 103 ope.
2 A 30 V DC Min. 100 x 103 ope.
0.5 A 125 V AC Min. 100 x 103 ope.
Inrush load* Inrush current : 7.5 A 30 V AC (250 ms time)
Steady state current : 1.5 A 30 V AC (cosφ=0.4)
Min. 200 x 103 ope.
(Switching frequency ON : OFF=1s : 9s)

* When using at 7.5 A, please refer to "GUIDELINES FOR USAGE, Max. switching current".

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)